<?xml version="1.0"?>
<records>
  <record>
    <language>eng</language>
    <publisher>Ansari Education and Research Society</publisher>
    <journalTitle>Journal of Ultra Chemistry</journalTitle>
    <issn>0973-3450</issn>
    <eissn>2319-8036</eissn>
    <publicationDate>December 2007</publicationDate>
    <volume>3</volume>
    <issue>2</issue>
    <startPage>127</startPage>
    <endPage>130</endPage>
    <doi>juc</doi>
    <publisherRecordId>649</publisherRecordId>
    <documentType>article</documentType>
    <title language="eng">Nickel (II) ion sensing with Aradlite-matrix based membrane sensor - It's analytical application</title>
    <authors>
      <author>
        <name>J. Thamarai Selvi </name>
        <affiliationId>1</affiliationId>
      </author>
      <author>
        <name>S.V. Seeja</name>
        <affiliationId>1</affiliationId>
      </author>
    </authors>
    <affiliationsList>
      <affiliationName affiliationId="1">Department of Chemistry, Avinashilingam University for Women, Coimbatore - 641 043, Tamilnadu, INDIA</affiliationName>
    </affiliationsList>
    <abstract language="eng">&lt;p&gt;A heterogeneous precipitate have been as ion carriers of the preparation of Nickel (II) selective membrane sensors.&amp;nbsp; The electrodes give near-nernstian responses in the linear concentration range of 1N to 1x10&lt;sup&gt;-5&lt;/sup&gt; N with detection limits of the order of 10&lt;sup&gt;-5&lt;/sup&gt;N.&amp;nbsp; The stable potentiometric signals are obtained with in a short time period of 7 seconds.&amp;nbsp; The effects of pH and the effect of medium have been studied found to give better responses. Selectivity coefficient values&amp;nbsp;&amp;nbsp; evaluated using fixed interference method.&amp;nbsp; The sensors have also been as a indicator electrodes in potentiometric titrations of Nickel (II) ions with EDTA and its determination in alloy analysis.&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/p&gt;&#xD;
&#xD;
&lt;p&gt;&lt;em&gt;Key words : &lt;/em&gt;Nickel(II), Aradlite-matrix, .&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/p&gt;&#xD;
</abstract>
    <fullTextUrl format="html">https://journalofchemistry.org/paper/649/</fullTextUrl>
    <keywords>
      <keyword language="eng">Department of Chemistry, Avinashilingam University for Women, Coimbatore - 641 043, Tamilnadu, INDIA</keyword>
    </keywords>
    <keywords>
      <keyword language="eng">Aradlite-matrix</keyword>
    </keywords>
    <keywords>
      <keyword language="eng">selective membrane sensors</keyword>
    </keywords>
  </record>
</records>
