<?xml version="1.0"?>
<records>
  <record>
    <language>eng</language>
    <publisher>Ansari Education and Research Society</publisher>
    <journalTitle>Journal of Ultra Chemistry</journalTitle>
    <issn>0973-3450</issn>
    <eissn>2319-8036</eissn>
    <publicationDate>August 2009</publicationDate>
    <volume>5</volume>
    <issue>2</issue>
    <startPage>149</startPage>
    <endPage>152</endPage>
    <doi>juc</doi>
    <publisherRecordId>698</publisherRecordId>
    <documentType>article</documentType>
    <title language="eng">Potentiometric determination of Nickel (II) ion using Nickel triphenyl phosphine complex of N (1-phenyl-3-methyl-4- benzoyl-5-hydroxy pyrazolin) 2-Amino phenol imine Schiff base</title>
    <authors>
      <author>
        <name>M. Gowri</name>
        <affiliationId>1</affiliationId>
      </author>
      <author>
        <name>J. Thamarai Selvi</name>
        <affiliationId>1</affiliationId>
      </author>
      <author>
        <name> P. Arul Priya</name>
        <affiliationId>1</affiliationId>
      </author>
      <author>
        <name> G. Shanthi</name>
        <affiliationId>1</affiliationId>
      </author>
    </authors>
    <affiliationsList>
      <affiliationName affiliationId="1">Department of Chemistry, Avinashilingam University for women, Coimbatore - 641043 (INDIA)</affiliationName>
    </affiliationsList>
    <abstract language="eng">&lt;p style="text-align: justify;"&gt;The [Ni(PPh&lt;sub&gt;3&lt;/sub&gt;) (BPOAP)] complexes have been used as ion carriers for the preparation of Nickel (II) ion selective membrane sensors. This electrode gives near Nerstian responses in the linear concentration range of 1&amp;times;10&lt;sup&gt;-6&lt;/sup&gt; to 1 M with electron limits of the order of 10&lt;sup&gt;-6&lt;/sup&gt;M. The stable potentiometric signals are obtained with in a short time period of 5 seconds; the effect of pH and the effect of medium have been studied. Selectivity co efficient values (log &lt;img src="file:///D:/atif/Drive%20E%20data/desktop%20data/Business/journal/JUC/JUC/abs_vol5(2)/AbstrOE1.JPG" style="height:12px; width:20px" /&gt;,M ) have been evaluated using fixed interference method (FIM).&lt;/p&gt;&#xD;
&#xD;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;&#xD;
</abstract>
    <fullTextUrl format="html">https://journalofchemistry.org/paper/698/</fullTextUrl>
    <keywords>
      <keyword language="eng">Complexes</keyword>
    </keywords>
    <keywords>
      <keyword language="eng">selective membrane sensors</keyword>
    </keywords>
  </record>
</records>
