<?xml version="1.0"?>
<records>
  <record>
    <language>eng</language>
    <publisher>Ansari Education and Research Society</publisher>
    <journalTitle>Journal of Ultra Chemistry</journalTitle>
    <issn>0973-3450</issn>
    <eissn>2319-8036</eissn>
    <publicationDate>December 2005</publicationDate>
    <volume>1</volume>
    <issue>2</issue>
    <startPage>55</startPage>
    <endPage>58</endPage>
    <doi>juc</doi>
    <publisherRecordId>840</publisherRecordId>
    <documentType>article</documentType>
    <title language="eng">SIMPLE ANALYSIS OF CEPHALEXIN AND CEFACLOR IN PHARMACEUTICALS PREPARATION BY TLC WITH UV DETECTION</title>
    <authors>
      <author>
        <name>Shweta Sharma</name>
        <affiliationId>1</affiliationId>
      </author>
      <author>
        <name>S. Singh</name>
        <affiliationId>2</affiliationId>
      </author>
      <author>
        <name>S. Baghel</name>
        <affiliationId>3</affiliationId>
      </author>
    </authors>
    <affiliationsList>
      <affiliationName affiliationId="1">Department of Chemistry, Sarojini Naidu Govt. Girls P.G. College, Bhopal u2013INDIA</affiliationName>
      <affiliationName affiliationId="2">Joint Director, M.P. Council of Science and Technology, Bhopal (INDIA)</affiliationName>
      <affiliationName affiliationId="3">Assistant Professor, Sarojini Naidu Govt. Girls, P.G. College, Bhopal (INDIA)</affiliationName>
    </affiliationsList>
    <abstract language="eng">&lt;p style="text-align: justify;"&gt;The objective of this investigation was to develop a simple thin layer chromatographic method for the determination of Cephalexin and Cefaclor, Cephalosporins widely used in clinical practice. Thin Layer Chromatography of selected Cephalosporins was performed on precoated silica gel plates with concentrating zone (20x20 cm) by development in different mobile phase.&lt;br /&gt;&#xD;
Quantitative evaluation was performed by measuring the absorbance reflectance of the analyte spots at lambda=245 nm and by the detecting reagents. This method is rapid, selective, precise and accurate and thus can be used for the routine analysis of Pharmaceuticals formulations in quality control laboratories of the Pharmaceutical Industry.&lt;/p&gt;&#xD;
</abstract>
    <fullTextUrl format="html">https://journalofchemistry.org/paper/840/</fullTextUrl>
    <keywords>
      <keyword language="eng">EPHALEXIN AND CEFACLOR </keyword>
    </keywords>
    <keywords>
      <keyword language="eng">PREPARATION BY TLC </keyword>
    </keywords>
  </record>
</records>
