<?xml version="1.0"?>
<records>
  <record>
    <language>eng</language>
    <publisher>Ansari Education and Research Society</publisher>
    <journalTitle>Journal of Ultra Chemistry</journalTitle>
    <issn>0973-3450</issn>
    <eissn>2319-8036</eissn>
    <publicationDate>May 2019</publicationDate>
    <volume>15</volume>
    <issue>3</issue>
    <startPage>23</startPage>
    <endPage>29</endPage>
    <doi>http://dx.doi.org/10.22147/juc/150301</doi>
    <publisherRecordId>900</publisherRecordId>
    <documentType>article</documentType>
    <title language="eng">Extraction optimization of cupric ions by cloud point</title>
    <authors>
      <author>
        <name>RAHMOUNA SEMMOUD</name>
        <affiliationId>1</affiliationId>
      </author>
      <author>
        <name> SANAA NAIT-TAHAR</name>
        <affiliationId>1</affiliationId>
      </author>
      <author>
        <name>MOHAMED AMINE DIDI</name>
        <affiliationId>1</affiliationId>
      </author>
    </authors>
    <affiliationsList>
      <affiliationName affiliationId="1">Department of chemistry, Laboratory of Separation and Purification Technologies, Box 119, Tlemcen University u2013 13000 (Algeria)</affiliationName>
    </affiliationsList>
    <abstract language="eng">&lt;p style="text-align:justify"&gt;Several pre-concentration and separation techniques are known, as well as the cloud point extraction (CPE). In order to optimize the operation of a coacervate extraction process, it is extremely important to take into account, on the one hand, the choice of the surfactant, which must be the most efficient and, on the other hand; and to know well the evolution of the factors that governs the effectiveness of this technique.&lt;/p&gt;&#xD;
&#xD;
&lt;p style="text-align:justify"&gt;Investigations on the extraction of cupric ions by Triton X-100, the ionic liquid denoted LIM and the potassium nitrate (KNO&lt;sub&gt;3&lt;/sub&gt;) were produced using the technique of extraction by cloud point (coacervat). The extraction experiments showed that the cupric ions were extracted with the following optimal parameters: pH 2.0; Concentration of LIM equal to 0.08M; Triton X-100 mass ratio equal to 0.1%; KNO&lt;sub&gt;3&lt;/sub&gt; mass ratio equal to 1%; at ambient temperature.&lt;/p&gt;&#xD;
</abstract>
    <fullTextUrl format="html">https://journalofchemistry.org/paper/900/</fullTextUrl>
    <keywords>
      <keyword language="eng"> Copper (II)</keyword>
    </keywords>
    <keywords>
      <keyword language="eng"> Cloud point extraction</keyword>
    </keywords>
    <keywords>
      <keyword language="eng"> Ionic liquid</keyword>
    </keywords>
    <keywords>
      <keyword language="eng"> Nonionic surfactant</keyword>
    </keywords>
  </record>
</records>